Hospital Care

JMS Stomach Tube

for external feeding – provides an alternative route to assist the digestive tract for patients with eating disorders or difficulty swallowing with the introduction of food, fluids, or drugs.

  • Flexible tube & Catheter Connector with one or more Eye Holes design

  • Connect to an enteral “Giving Set” to transfer the nutrient to gastro-intestinal tract

  • Provide an alternate route for food, fluids, and medications when normal eating is impaired

  • Designed for nasogastric introduction for nutritional, and/or medication and aspiration of intestinal secretion

Available in:

French Size (Fr)

Tube Length (cm)

12

120

14

120

16

120

18

120

20

120

JMS Feeding Tube​

for external feeding – provides an alternative route to assist the digestive tract for patients with eating disorders or difficulty swallowing with the introduction of food, fluids, or drugs that feed people

  • Flexible tube & Catheter Connector with one or more Eye Holes design

  • Connect to an enteral “Giving Set” to transfer the nutrient to gastro-intestinal tract

  • Placement may be temporary for the treatment of acute conditions or lifelong in the case of chronic disabilities

  • Designed for Neonatal and Paediatric Nutritional feeding

Available in:

French Size (Fr)

Tube Length (cm)

4

40

5

40

5

120

6

40

6

80

8

40

8

120

10

120

12

120

Infusion Set Type-200 Series

  • Non-vented set

  • Designed to suit fluid replenishment using flexible bag, or with an attached air needle for semi-rigid containers or glass bottles

  • ISO 8536-4 compliant spike and drip chamber (15, 19 drop/ml)

  • ISO 594 no. 1 & 2 compliant end-connection

  • Injection site (Y-site, rubber tube)

  • Sterilization validated according to EN 550 Standards

Infusion Set Type-500 Series

  • Vented set (Air needle not required for venting)

  • Designed to suit fluid replenishment using rigid container as well as flexible bag

  • ISO 8536-4 compliant spike and drip chamber (15, 19 drop/ml)

  • 15u membrane filter to secures high bacteria filtration

  • Injection site (Y-site, rubber tube)

  • Sterilization validated according to EN 550 Standards

Infusion Set Type-Pediatric

Micro drip type. This incorporates a precise dripping port made of metal that provides accurate infusion rate control at 60 drops per ml. With a large size V-Clamp (roller clamp) for better flow rate adjustment

  • Non-vented set (Type 200) & vented (Type 500)

  • ISO 8536-4 compliant spike and drip chamber (60 drop/ml)

  • Large Size V-Clamp

  • ISO 594 no. 1 & 2 compliant end-connection

  • Injection site (Y-site, rubber tube)

  • 23G Vein Needle

  • Sterilization validated according to EN 550 Standards

Infusion Set with Buret

The buret with clear graduations in 1 ml interval allows precise solution volume setting and drip chamber with a micro drip orifice (60 drops per 1 ml) permits accurate infusion rate control.

  • ISO 8536-4 compliant spike & drip chamber (60 drop/ml)

  • Large Size V-Clamp

  • ISO 594 no. 1 & 2 compliant end-connection

  • Injection site (Y-site, rubber tube)

  • 23G Vein Needle

  • Sterile Pack - ETO Sterilization according to EN 550 Standards

Transfusion Set Type-5

  • Intravenous administration of Blood and Blood Components

  • ISO 8536-4 compliant spike and drip chamber (60 drop/ml)

  • ISO 594 no. 1 & 2 compliant end-connection

  • Injection site (Y-site, rubber tube)

  • 18G Vein Needle

  • Sterilization validated according to EN 550 Standards

Transfusion Set Type-Y

Used for simultaneous or alternate administration of blood and solution. The spikes are designed to fit both with blood bags and solution containers

  • Intravenous administration of Blood and Blood Components

  • ISO 8536-4 compliant spike and drip chamber (60 drop/ml)

  • ISO 594 no. 1 & 2 compliant end-connection

  • Injection site (Y-site, rubber tube)

  • 18G Vein Needle

  • Sterilization validated according to EN 550 Standards

Transfusion Set with Buret

It is especially useful and needed when to get small volume blood transfusion for neonatal, premature babies and pediatrics.

Scalp Vein

A winged infusion set with a specialized device used for drawing blood from vein and intravenous (I.V.) therapy into a vein. 

  • Super thin-wall needle provides large inner diameter that enables sufficient flow and smooth infusion.

  • Perfect geometry of needle profile that is individually silicone for sharpness and painless venepuncture

  • Optimum softness of Luer connector offers firm connection with Luer adaptor, 3-Way stopcock, syringes etc

  • Compliance to ISO 6009 standards using color-codes for needle gauge size identification

Available in:

Gauge (O.D)

Tube Length (cm)

19

30

20

30

21

30

22

30

23

30

24

30

25

30

27

30

Mucus Extractor

Mucus is a single device to secretion from the oral cavity or used with a suction machine to maintain an airway by removing secretions from the mouth, throat, or lungs. It is particularly important in neurological diseases where the ability to cough or swallow is impaired.

  • Comprised of a graduated transparent container with 2 flexible frosted tubes leading to it

  • One tube is open-ended with an eye hole for nasal insertion while another tube ends with a mouthpiece for suction purpose

  • Designed for aspiration of secretion from oropharynx in neonatal cases ensuring free respiration or obtaining mucus specimen for microbiological examination

Available in: 10 FR

Extension Tube

A device to connect and extend the infusion or transfusion sets for administration liquids, medication, or blood into the circulation system by using of intravenous catheter and cannula to allow a greater distance between the patient. With connects with medical device that use standard Luer lock or luer slip connector

  • Designed for extending intravenous lines to transfusion set, syringe pump, three-way stopcock or accessories that require intermittent injection

  • ISO 594/ number 1&/2 compliant end-connection

  • Medical Grade PVC, kink resistant for smooth fluid

  • Sterile Pack - ETO sterilization according to EN 550 Standards

Available in: Type 1, Type 2, Type 3 

3 Way Stopcock with Extension Tube

A single-use sterile medical products meant to be used in conjunction with other devices during infusion therapy to restrict or isolate the flow of liquids or gases through pipes and provide other ports for the administration of any fluid (Medication)

  • Made of Polycarbonate material for excellent strength and biocompatibility

  • Special set with predefined channel flow pressure of 1 bar and 3 bar

  • Sterile Pack - ETO sterilization according to EN 550 Standards

Available in: Type 2

Safety Infusion Set

Helps prevent air infusion and infusion-related infection, reduces workload, saves time and costs.

  • Air-Stop

    JMS Safety Infusion Set is carefully designed to meet ISO requirements integrated with safe priming and improving efficiency for IV therapy. The carefully selected membrane is tasked to prevent air from passing through and limiting the risk of air embolism in patient. It also acts to prevent particulates from entering into patient’s body. Thus, there is no risk of air infusion into the patient when infusion solution in the fluid container is emptied during IV therapy.

  • Prime-Stop Filter

    The priming filter at the distal end on the Luer lock fitting is designed to prevent solution from passing through. This prevents solution leaking and protects it from contamination. Staff may attend to other work after setting up an IV set for priming with no risk of dripping solutions or drugs. The IV set does not need further attention until the priming is completed.

  • Needleless port

    Needleless injection port provides a safe and efficient way of injecting drug or medication when necessary. The port can be conveniently accessed by a needleless syringe or other Luer connector in a leak-proof procedure. This reduces the risk of needle prick injury to the nurse. It is also latexfree, reducing the possibility of contamination from the external environment and support multiple injections throughout the IV therapy session

  • Non-DEHP

    JMS understand the safety concerns of using DEHP medical device in clinical practice. As such JMS is offering medical devices with non-DEHP material.